Shenzhen Maixiang Technology Co.,Ltd

Shenzhen Maixiang Technology Co.,Ltd

Manufacturer from China
Active Member
8 Years
Home / Products / Vehicle Loop Detector /

Vehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate System

Contact Now
Shenzhen Maixiang Technology Co.,Ltd
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissSherry
Contact Now

Vehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate System

Ask Latest Price
Brand Name :MAX
Model Number :PD132
Certification :CE, ISO, SGS
Place of Origin :China
MOQ :1 set
Price :negotiation
Payment Terms :L/C, T/T, Western Union
Supply Ability :800 set/month
Delivery Time :3-10 working days after received your payment
Packaging Details :Export Wooden Case
Dimensions :78x40x108 Mm (WxHxL)
Color :Red/Black
Power Suppply :240VAC/ 110VAC/12VDC/24VDC
Working frequency :20-300uh
Reaction Time :100ms
Net Weight :300g
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Vehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate System

Main Characteristics:


B1) Supply voltage AC: 220V, 110V, 24V, 12V
B2) Supply voltage DC: 24V, 12V
B3) Sensitivity: adjustable in 3 increments (high .medium. low)
B4) Storage temperature: -40°C to +85°C
B5) Reaction time: 100ms
B6) Loop connection wiring: Maximum length 200 meters,
B7) Twisted at least 20 times per meter
B8) Net Weight: 300g

Install Detector :

The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn’t fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as “Loop installation guide”).

Vehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate System

Vehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate SystemVehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate SystemVehicle Loop Detector Single Channel Loop PD-132 In Barrier Gate System

Operation and Indication
Whenthe power is applied, the red Power LED will glow and the detector is tuning,the green Check LED blink about 3 seconds. The green LED will also glow whenever a vehicle is detected passing over the inductive loop. If a loop fault
exists the green LED will come on and flash indicating a fault.
Loopno connected: Loop too small:
Looptoo large:
Frequency
Thefrequency can be set by the two DIP switch on the circuit board. Disconnect power and then take down the detector from the socket, remove the shell. DIP6 (LA) is used for setting the frequency. ON: working in low frequency. OFF:working in high frequency The detector will be calibrated automatically when connecting the power after adjusting the frequency. Notice: High frequency has been set. The installation distance is too close between the two loop
detectors, the different frequency can be setting by the user.Sensitivity The response sensitivity can be set using the threestage switch on the front. The setting L corresponds to the lowest sensitivity. M is the medium sensitivity and H is the highest sensitivity. After the sensitivity has been set, a reset and a calibration automatically takes place.
Attention If thedetector isn’t working normally, you must check the loop and wiring at first, and then alter the frequency or the sensitivity.
Output Relay
Whenvehicle press loop, the relay's output mode set by the main control panel switch. TLD-410 has two loops, corresponding to two output relays. loop1 (7-8 pin) corresponds to the relay 1 (5, 6, 10 pin) output for the existence of a fixed output signal, the loop 2 (7,9 pin) corresponds to the relay 2 (3,4,11 pin) and pull the output signal from the DIP code switch DIP1, DIP2, DIP3 (SW0,SW1, SW2) decision.ListenRead phonetically.Vehiclepresence check model output setting Vehicle direction (count) check mode output signal and setting:
Reset
Thedetector automatically reset and tune to the inductive loop when the power is applied, whether on initial installation or after any break in power supply.Should it be necessary to retune the detector, as may be required after
changing any of the switches or after moving the detector from one installation to another.

A.Application Scope :

A1)Parking lot entrances vehicle detection ;
A2)Parking lot space information acquisition system ;
A3)Electronic police traffic lights snap shot system ;
A4)Traffic monitoring system .
Inquiry Cart 0