Shenzhen Maixiang Technology Co.,Ltd

Shenzhen Maixiang Technology Co.,Ltd

Manufacturer from China
Active Member
8 Years
Home / Products / Vehicle Loop Detector /

Two Relay Garage Door Opener Inductive Loop Vehicle Detector

Contact Now
Shenzhen Maixiang Technology Co.,Ltd
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissSherry
Contact Now

Two Relay Garage Door Opener Inductive Loop Vehicle Detector

Ask Latest Price
Brand Name :MAX
Model Number :PD-132
Certification :CE
Place of Origin :China
MOQ :1 set
Price :Negotiation
Payment Terms :Western Union, T/T, L/C/Paypal
Supply Ability :2000 set/month
Delivery Time :3-10 working days after received your payment
Packaging Details :Packed in bubble wrap firstly, and then reinforced with carton for outer packing.
Name :Inductive vehicle loop detector for Traffic Access Control
Supply voltage :230V AC , 115V AC, 24V DC/AC, 12V DC/AC
Storage temperature :-40°C to +85°C
Reaction time :100ms
Frequency range :20 kHz to 170 kHz
Sensitivity :Adjustable in 3 increments
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Two Relay Garage Door Opener Inductive Loop Vehicle Detector

Technical Data of inductive vehicle loop detector for Traffic Access Control

Name Inductive vehicle loop detector for Traffic Access Control
Brand name MAX
Model NO MXLD-133
Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC
( See the label on the detector)
Voltage tolerance AC: +10% / -15%
Voltage tolerance DC: ±15%
Power Consumption: 4.5VA
Output relays: 240V/5A
Operating temperature: -20°C to +65°C
Storage temperature: -40°C to +85°C
Frequency range: 20 kHz to 170 kHz
Reaction time: 100ms
Signal holding time: Unlimited
Sensitivity: Adjustable in 3 increments
Loop inductance: Total loop plus connection wiring: 50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiring: Maximum length 20 meters,twisted at least 20 times per meter
Size of Housing: 78x40x108 mm (L x W x H)

What is loop detector ?

Loop detectors are used wherever vehicles have to be detected. Like monitoring and safe guarding access ways for counting vehicles. The output signal can be used for controlling door and gate drive mechanisms, road barriers, controlling traffic light systems in car parks or activating card dispensers in car parks.

Application Scope :

Parking lot entrances vehicle detection ;

Parking lot space information acquisition system ;

Electronic police traffic lights snap shot system ;

Traffic monitoring system .

Features :

Reset Switch. Pressing the reset switch enables the detector to be manually reset during commissioning and
testing. This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection.
Switch selectable Sensitivity. The detect sensitivity is the minimum change in inductance required to produce a
detect output. (%L/L). Eight sensitivity settings are available on the switches to allow flexibility in configuration.
Sensitivity Boost. This feature sets the undetected level to maximum sensitivity and is used to prevent loss of
detection of high-bed vehicles.
Filter Option. This option is used to provide a delay of 2 Seconds between detection of the vehicle and switching
of the output relay. This delay is normally used to prevent false detection of small or fast moving objects.
Extend Option. When switched on this feature extends the presence output relay for 2 Seconds after the vehicle
has left the loop.
Permanent Presence. This feature ensures detection of the vehicle will be maintained when the vehicle is
parked over the loop for extended periods.
Pulse Relay Selection. The Pulse relay may be configured to energise on detection of a vehicle or to energise
when the vehicle leaves the loop.
Selectable Pulse Time. This feature sets the length of time that the pulse relay will be energised. 1 Second or 0.2 Second.

Vehicle loop detector Application:

Loop detectors are used wherever vehicles have to be detected. Like monitoring and safe guarding access ways to counting vehicles.

The output signal can be used for controlling door and gate drive mechanisms, operating barriers, controlling traffic light systems

in car parks or activating card dispensers in car parks.

HOW TO USE ?

1, The detector must be installed in a convenient weatherproof location as close to the loop as possible. Installation location must choose to stay away from the heat source, it around other devices must maintain a distance of at least 10mm (mustn't fix cling to the cabinet). A correct loop configuration and detector installation will ensure a successful inductive loop detection system. Loop of several important parameters include: loop figure, size, and turns, install methods (details as "Loop installation guide").

2, While the detector is tuning, the green Channel LED and red Power LED will be turn on. It remain about 2 seconds, then the green LED turn off. If a loop fault exists the Channel LED will come on and flash indicating a fault. If the fault is self-healing the detector will continue to operate. The green channel LED will also glow whenever a vehicle is detected passing over the inductive loop. The red Power LED at the top of the unit will remain on to indicate that the unit is powered.

HOW WE SERVE ?

1. -Your inquiry concerns about our products or prices will be replied in 12 hours

2. -One year guarantee ,Life-time service.

3. -Well-trained and experienced sales staffs answer all your inquires in fluent English

4. -Protection of your sales area, ideas of design and all your private information

5. -Deliver by air mail or ship for your orders

6. -Detailed installation manual and wiring diagram to make everything be easy

7. -Fast finishing time for you to become more competitive at your local market :3-5 days for small order.

Inquiry Cart 0